Quick answer
An inverter must cover the steady running load continuously and the largest single motor startup as a surge. A 600W running load with a 1,800W compressor start needs about 720W continuous and 2,400W of surge.
Result
The formula
continuous W = running W x headroom; surge W = running W + largest startup W
The DC current result is the number that decides cable size and the battery BMS rating, and it is where most 12V inverter installs go wrong.
The figures shown above are computed with these exact inputs: Running AC load 600 W, Largest startup surge 1800 W, Battery bank voltage 12 V.
Some of these are published standards and some are conventions. They are not the same kind of number, so each one is labeled.
| Assumption | Kind | Where it comes from |
|---|---|---|
| Inverter Efficiency: 0.85 | Convention | Typical pure sine inverter efficiency. Individual units publish their own figure. |
Every card below is in the page source. The calculator re-ranks them against your numbers and marks anything that falls short of what you just calculated.
At 2000W a 12V inverter can draw close to 200A, so it needs a battery with a BMS rated to match. Renogy publishes that draw.
Best for: A 200Ah lithium bank with a 200A BMS.
Check price on Amazon
A 4000W surge rating gives headroom for the startup spike of a compressor without nuisance shutdowns.
Best for: A residential fridge plus occasional high draw.
Check price on Amazon
The lowest cost 2000W pure sine unit here. Note that it is an inverter only, with no charger and no transfer switch.
Best for: Adding inverter capacity where a converter already handles charging.
Check price on AmazonResearched guidance, not professional advice. These results are planning figures from published standards and manufacturer specifications. Never exceed a conductor's rated ampacity, fuse every positive conductor close to the battery, never run a generator in an enclosed space because carbon monoxide is lethal and odorless, and have permanent AC wiring done by a qualified RV technician or licensed electrician.