Quick answer
Wire sizing has two separate tests and a conductor has to pass both. The first is ampacity: can the wire carry the current without overheating? The second is voltage drop: does enough voltage actually arrive at the other end? On 12 volt systems voltage drop almost always decides, because there is so little voltage to lose in the first place.
The formula doubles the run length, and that doubling is the most commonly missed step in RV wiring. Current flows out on the positive conductor and back on the negative, and it drops voltage in both. Check your own combination on the wire gauge calculator.
What gauge wire for 150 amps at 5 feet?
ABYC E-11 sets two voltage drop limits: 3 percent for critical circuits such as panel feeds and electronics, and 10 percent for non-critical circuits such as lighting. Both answers are below.
| Voltage drop limit | Applies to | Smallest conductor | Actual drop |
|---|---|---|---|
| 3 percent | Critical circuits, panel feeds, electronics | 2 AWG | 0.291 V (2.42%) |
| 10 percent | Non-critical circuits, lighting, accessories | 4 AWG | 0.462 V (3.85%) |
Published standard Source: ABYC E-11 voltage drop limits and ampacity, with NEC Chapter 9 Table 8 conductor resistance.
How does the answer change with run length?
Voltage drop is directly proportional to length, so doubling the run doubles the drop and pushes you up the gauge table. This is the same 150 amps at a range of distances.
| One-way run | Smallest conductor | Voltage drop | Voltage arriving |
|---|---|---|---|
| 3 ft | 4 AWG | 0.277 V | 11.72 V |
| 5 ft | 2 AWG | 0.291 V | 11.71 V |
| 10 ft | 2/0 AWG | 0.29 V | 11.71 V |
| 15 ft | 3/0 AWG | 0.345 V | 11.66 V |
| 20 ft | None up to 4/0 | - | - |
| 25 ft | None up to 4/0 | - | - |
| 30 ft | None up to 4/0 | - | - |
Published standard Source: NEC Chapter 9 Table 8 resistance, ABYC E-11 ampacity.
Would 24 volts solve this?
Yes, and dramatically. At 24 volts the same power moves at half the current, and voltage drop as a percentage falls by a factor of four. The same load at 24 volts needs only 8 AWG over 5 feet. This is the whole argument for higher system voltage in a large build, and it is why big inverters are increasingly sold in 24 and 48 volt versions.
What fuse goes with 150 amps?
A continuous 150 amp load is protected at 125 percent, which is 187.5 amps, rounded up to the next standard rating of 200 amps. The conductor must be rated to carry at least as much as the fuse, because the fuse exists to protect the wire. Fitting a fuse larger than the wire can carry defeats the entire point of having one. See the fuse size calculator.
BOJACK 200A Inline ANL Fuse Holder with Fuse
$15.99Takes 0 through 4 AWG, which covers the cable sizes an RV inverter circuit actually uses.
Best for: Fusing an inverter feed at the battery.
Check price on Amazon
iRhapsody 200A ANL Fuse Holder Kit, 3 Pack
$13.99Three holders in one pack, which is usually what a full build needs once the inverter, the solar and the DC-DC feed are all fused.
Best for: Fusing several circuits in one build.
Check price on AmazonCable, lugs and overcurrent protection
TOPDC 4 AWG Battery Cable Pair, 18 in
$11.98Pure copper with factory-crimped 3/8 inch lugs. A crimped lug from the factory beats a hand-twisted connection every time.
Best for: Short battery to busbar runs.
Check price on Amazon
4 AWG Battery Inverter Cable, 2 ft Pair
$20.99A 2 foot pair suits an inverter mounted close to the bank, which is where an inverter should be.
Best for: Inverter to battery on a short run.
Check price on Amazon
BOJACK 200A Inline ANL Fuse Holder with Fuse
$15.99Takes 0 through 4 AWG, which covers the cable sizes an RV inverter circuit actually uses.
Best for: Fusing an inverter feed at the battery.
Check price on Amazon
iRhapsody 200A ANL Fuse Holder Kit, 3 Pack
$13.99Three holders in one pack, which is usually what a full build needs once the inverter, the solar and the DC-DC feed are all fused.
Best for: Fusing several circuits in one build.
Check price on AmazonFrequently asked questions
- What gauge wire do I need for 150 amps at 5 feet?
- 2 AWG copper, if you are holding to the 3 percent voltage drop limit ABYC applies to critical circuits. That conductor loses about 0.291 volts over the round trip. On a non-critical circuit such as lighting, where 10 percent is acceptable, 4 AWG would do.
- Why does the run length get doubled in the voltage drop formula?
- Because current has to return. It flows out along the positive conductor to the load and back along the negative conductor to the battery, and it drops voltage in both directions. A 10 foot one-way run is 20 feet of conductor as far as voltage drop is concerned. Forgetting this halves the calculated drop and undersizes the cable by a full step or more.
- Is ampacity or voltage drop the limiting factor at 12 volts?
- Voltage drop, nearly always. A 12 volt system has so little voltage to spare that a 3 percent limit is only about 0.36 volts, and a conductor big enough to stay under that is usually well above what ampacity alone requires. On higher voltage systems the balance shifts and ampacity starts to govern more often.
- Can I use welding cable or automotive wire instead?
- Welding cable is fine electrically and is finely stranded, which makes it flexible and easy to route, but check that the insulation is rated for the temperature and oil exposure where it runs. Cheap automotive wire is sometimes copper clad aluminum rather than pure copper, which has higher resistance than the gauge suggests and will not meet these figures. Confirm pure copper before buying.
Wiring safety. Never exceed a conductor's rated ampacity, and always fuse a circuit at or below what the wire can carry, because the fuse protects the wire rather than the appliance. Fuse every positive conductor as close to the battery as practical. Use proper crimped lugs and heat shrink rather than twisted joints, support cable so it cannot chafe through on a frame edge, and keep the battery compartment ventilated. Permanent AC wiring is work for a qualified RV technician or a licensed electrician.